Dew Point Meter/Ventilated Dry and Wet Meter
Home - Products - Temperature and Humidity Calibration Chamber - Dew Point Meter/Ventilated Dry and Wet Meter - DY-LD01 Cold Mirror Dew Point Apparatus(Input Type)-20℃~+95℃
DY-LD01 chilled mirror dew point meter (immersion type) -20℃~+95℃ is an instrument specially used for testing dew point temperature, ambient temperature and relative humidity. The product adopts the chilled mirror principle, touch screen control system, and fully automatic continuous analysis. The dew point meter has high accuracy, wide range, good stability, and no drift. It is widely used in the fields of temperature and humidity measurement of measurement units.
The chilled mirror dew point meter (self-produced) has real-time display of the entire curve, touch screen operation, Chinese and English dual interface, and easy operation; automatic balancing system, short measurement time; mirror contamination self-detection function, manual mirror cleaning, data storage, query and printing functions; long-term stability, good repeatability, online analysis, and users can perform single-point or multi-point calibration.
√ Range width: -20℃ ~ +95℃
√ High accuracy: ±0.2℃ (optional ±0.1℃)
√ High resolution: 0.01℃
√ Real-time display of the whole curve
√ Touch screen operation, Chinese and English double interface, easy to operate
√ Automatic balance system, short measurement time
√ Mirror pollution self-detection function, manual cleaning of the mirror
√ Data storage, query and print functions
√ Long-term stability, good repeatability, can be done online analysis
√ User can do single or multi-point calibration
Range | -20℃~+95℃ (Note 1) | |
Accuracy | ≤±0.15℃~±0.2℃ | |
Resolution | 0.01℃ 0.01%RH | |
Display interface | Chinese display, TFT color LCD touch screen,Real-time temperature, humidity, balance process curve, balance indication, etc. | |
Uncertainty | ≤±0.1℃~0.15℃ | |
Repeatability | ≤±0.05℃ | |
Dew point sensor | Humidity sensor | First level probe |
Dew point temperature range | -20℃-95℃ | |
Relative humidity range | 0-100%RH | |
Accuracy | ±0.2℃ (optional ±0.15℃) | |
Temperature Sensor | Temperature sensor | PT100 Class A |
Temperature range | -40℃~+60℃ | |
Accuracy | ±0.1℃ | |
Cooling method | Secondary semiconductor Peltier cooling | |
Alarm function | 1. Sample gas flow abnormal alarm 2. Mirror contamination alarm 3. Humidity setting value alarm | |
Traceability | Trace back to MBW973 standard certificate | |
Environmental temperature and humidity | Environmental temperature: -20℃~+50℃; humidity environment ≦95% | |
Appearance size (mm) | 250mm×300mm×100mm | |
Random accessories | Host×1, power cord×1, temperature sensor×1 set, dew point sensor×1, dew point sensor line×1, three packs×1, instruction manual×1, portable instrument box×1 | |
Weight | ≤3KG (including aluminum chassis≤6.5KG) | |
Power supply voltage and power | 90~220V AC 50~60Hz 60W (260) | |
Signal output | Serial communication R232 |
Note 1: As the ambient temperature increases, the cooling capacity of the instrument decreases and the lower limit of the measurement range increases.